Roof
ROOF MOUNTED COOLERS

Technical specifications
Cooling capacity from 3 to 8 kw with setting temperature at 45°C.
Axial fans commanded by pressure switch relieves for condensation control.
Component’s Lay-out Component’s Lay-out Roof mounted air diffusion groups Roof mounted air diffusion groups
Chilled Fluid temperature variable from 5 to 20°C.
Single or double cooling circuit, one or two hermetic SCROLL or Rotary compressors, brazed stainless steel plate heat exchangers.
Exposed Refrigerant gauges.
Hydraulic circuit including stainless steel tank and pump.
Electrical panel on board or with remote control, electronic temperature controller and SOFT START system for the slow compressors start-up. Power supply 220 and 380V.
Solid base structure made by steel and aluminium panels.
Engineered according to legislation.